Biological Indicator Test Strip
Beya Medical Biological Indicator Test Strips are small strips of special filter paper inoculated with bacterial spores, either Bacillus atrophaeus (BA) for ethylene oxide and dry heat sterilization or Geobacillus stearothermophilus (GS) for saturated steam sterilization. Request form
Don’t know how to order? Read this section
Request form
SKU
Biological Indicator Test Strip
Categories Biological Indicator, Biological Indicator Test Strip, Sterilization Control, Washing Control Apparatus
Tag Biological Indicator Test Strip
Detail Description
Biological Indicator Test Strip Beya Medical Biological Indicator Test Strips are small strips of special filter paper inoculated with bacterial spores, either Bacillus atrophaeus (BA) for ethylene oxide and dry heat sterilization or Geobacillus stearothermophilus (GS) for saturated steam sterilization. Each strip is packaged in a glassine envelope and is used to validate or requalify sterilization processes.. Bacillus atrophaeus (ATCC 9372) 10^6 spores per strip. Instructions for use Identify Beya Medical Biological Indicator Test Strips envelope by writing on its back the sterilizer number (in case of having more than one), load number and processing date. Pack it in appropriate package along with material to be sterilized, according to recommended sterilization practices. Place the envelope in those areas you a priori consider more inaccessible for sterilizing agent. A typical problematic area is the load center. Sterilize as usual. After the sterilization process has finished, you can: Remove the Beya Medical Biological Indicator Test Strips envelope from the package for processing and incubation. For Ethylene Oxide sterilization, you can aerate the package containing the biological indicator with the rest of the load or remove the biological indicator from the sterilization package for incubation in MC-BT10 culture medium or any other appropriate growth medium prior to material aeration. Tear up the envelope at one end very carefully under sterility conditions (eg. laminar flow cabinet) and transfer spore strip with a sterile clamp MC-BT10 Growth Medium tube, or to any other appropriate growth medium. IMPORTANT! Use latex gloves and chin strap when transferring spore strips from the envelope to growth medium tube. WARNING! Avoid spore strip contact with any kind of surface including the outer part of growth medium tube and of Beya Medical Biological Indicator Test Strips envelope. IMPORTANT: Use a non-sterilized spore strip as a positive control at least once per day, when a sterilization cycle is run. Both, processed spore strip and the strip used as positive control must belong to the same batch. Positive control guarantees that the incubation was carried out under appropriate conditions. Incubate processed spore strips along with the strip used as positive control during a maximum of 48 hours at 37±2 ºC. It is advisable to make observations every 10 hours. Color change of MC-BT10 Growth medium to yellow means a failure on sterilization process. If after 48 hours no colour change is visible on MC-BT10 Growth Medium, the result is negative (i.e. the sterilization process was successful). MC-BT10 Indicating Medium used for incubating the spores strips which have not been sterilized (positive control) should turn to yellow in order for the results to be valid. Additional Information PACKAGING : 100 PER BOX REGULATION : ISO 13485, ISO 11138-1, ISO 11138-2 ,ISO 11138 – 4 POPULATION : 10^6 SPORES PER CARRIER READOUT : 48 HOURS INCUBATION TEMP : 37 ± 2 ºC
How To Order Products
Select Product
Browse website and select or open the product that you want to order.
Submit Form
Fill the form with your name, email where we will contact you back, and share you requirements in detailed message.
Get Quotation
Get a detailed quotation with pricing, delivery time, and payment terms.
Receive Your Product
Product shipped safely to your doorsteps, and ready for your CSSD needs







